COMMAND
NAME
DESCRIPTION
NO.
COMMAND SYNT
A
X
COMMAND
ARGUMENT 1
ARGUMENT 2
ARGUMENT 3
ARGUMENT 4
RESPONSE
FFT DSP
Settings
Sets/Reads FFT DSP
related variables.
FFT Sample/Second:
0 – Automatic
1 – 8000 samples/sec
2 – 4000 samples/sec
3 – 2000 samples/sec
4 – 1000 samples/sec
5 – 500 samples/sec
21
FT
M
FFT Algorithm Mode:
E- Enable
D- Disable
alue> E or D FTM: Example: FTM:E No Argument (Ret. Current settings) FTM: Example: FTM:E T FFT T rigger Level: 0 – Auto [1-4095] - Manual [0-4095] FTT : Example: FTT :60 No Argument (Ret. Current settings) FTT : Example: FTT :60 S FFT Sample/Second (manufacture only , do not change*) [0-5] FTS: Example: FTS:1 No Argument (Ret. Current settings) FTS: Example: FTS:1,1000 D FFT Damping (manufacture only , do not change*) alue> E or D FTD: Example: FTF:D No Argument (Ret. Current settings) FTD: Example: FTF:D N FFT Minimum Noise Threshold for Auto (manufacture only , do not change*) [0-5000] FTN: Example: FTN:500 No Argument (Ret. Current settings) FTN: Example: FTN:500 A Attenuation Mode and Ta rget Level A or M [0-4095] FT A: Example: FT A:M,1000 No Argument (Ret. Current settings) FT A: Example: FT A:M,1000