Pulse
Output
Sets and controls action of the
programmable Pulse Output
cir
cuitr
y.
NOTE: Unit/Pulse
value has to be entered:-for
V
o
lumetric flow conditions
in currently selected volume EU
-for Mass flow conditions
in currently selected mass EU
EU has to be not time based.
It is recommended to set the
unit/pulse value equal to the
maximum flow in the same
units per second. This will limit
the pulse to no faster than one
pulse ever
y second.
Example: Maximum flow rate:
1200 liter/min (1200 liter/min =
20 liters per second)
If Unit/Pulse is set to 20 liters
per pulse, the output will pulse
once ever
y second.
13
P
C (flow
configuration)
V
-volum. flow
M-mass flow
alue> (Unit/Pulse) V o lumetric flow - current V o lumetric E.U. Mass flow - cur- rent mass EU (example: 10 litr/pulse) PCV : Example: PCV :V ,10 Or PCM: Example: PCM:M,2.5 T (Pulse active T ime in ms) [10 -13000 ms] PT : Example: PT :1000 D (disable pulse output)* P:D E (enable pulse output) P:E Q (read current pulse output Queue value) PQ: (number of pulses) S (setting status) PS:Mode,FlowConditions, Unit/Pulse,PulseT imeInter val Fluid Density for standard conditions Read and set Fluid Density for standard conditions in g/cm3 NOTE: it is not measured density . 14 FD (New Density V alue) 0.0001 Density 10.0 g/cm3 FD: Example: FD:1.293 No Argument (Returns Current Density in g/cm3) FD: Example: FD:1.293