Aalborg Vortex Insertion User Manual
Page 90
85
COMMAND
NAME
DESCRIPTION
NO.
COMMAND SYNT
A
X
COMMAND
ARGUMENT 1
ARGUMENT 2
ARGUMENT 3
ARGUMENT 4
RESPONSE
Optical
Outputs
Assigns action of the two
optical outputs. The optical
output becomes active when
the condition specified by an
Argument 2 becomes true.
Argument 2:
D
- no action (disabled*)
FL
- low flow alarm
FH
- high flow alarm
FR
- Range between High &
Low alarms
T1
- T
o
t#1 reading > limit
T2
- T
o
t#2 reading > limit
TL
- low temp. alarm
TH
- high temp. alarm
TR
- Range between High &
Low temp. alarms
PL - low press. alarm
PH - high press. alarm
PR
- Range between High &
Low press. alarms
DE
- Diagnostic Events
M
- Manual On (enabled)
11
O
1 (output #1)
2 (output #2)
D *
O1:D or O2:D
FL
O1:FL or O2:FL
FH
O1:FH or O2:FH
FR
O1:FR or O2:FR
T1
O1:MT or O2:MT
T2
O1:PT or O2:PT
TL
O1:TL or O2:TL
TH
O1:TH or O2:TH
TR
O1:TR or O2:TR
PL
O1:PL or O2:PL
PH
O1:PH or O2:PH
PR
O1:PR or O2:PR
DE
O1:DE or O2:DE
M
O1:M or O2:M
S (read current
settings)
O1:D or O2:D