UART Error Codes:
1 - Not Supported Command or Back Door is not enabled.
2 - Wrong # of Arguments.
3 - Address is Out of Range (MR or MW commands).
4 - Wrong # of the characters in the Argument.
5 - Attempt to Alter Write Protected Area in the EEPROM.
6 - Proper Command or Argument is not found.
7 - Wrong value of the Argument.
8 - Reserved.
9 - Manufacture specific info EE KEY (wrong key or key is disabled).
Diagnostic and System events codes and bit position:
Code
Event Description
Bit position
0
CPU Temp. High
0x0000001
1
Freq > HiLimit
0x0000002
2
High Flow Alm.
0x0000004
3
Low Flow Alarm
0x0000008
4
High Temp Alm.
0x0000010
5
Low Temp Alm
0x0000020
6
High Pres Alm.
0x0000040
7
Low Press Alm.
0x0000080
8
Tot#1 > Limit
0x0000100
9
Tot#2 > Limit
0x0000200
10
OptPulse Queue
0x0000400
11
Flow Turbulen.
0x0000800
12
Flow < Cut Off
0x0001000
13
Event Log Over
0x0002000
14
Data Log Over.
0x0004000
15
System L Event
0x0008000
System Events:
16
PEZO SENS. FAULT
0x0010000
17
TEMP SENS. FAULT
0x0020000
18
PRES SENS. FAULT
0x0040000
19
SER. COMM. ERROR
0x0080000
20
EEPROM ACC ERROR
0x0100000
21
BATTERY FAILURE
0x0200000
22
POWER ON EVENT
0x0400000
23
PASSWORD EVENT
0x0800000
24
FATAL ERROR
0x1000000