IntelliStripe 320 Command Reference
46
Byte Field Description
1-n
ATR Answer to Reset as received from the card.
WARM RESET COMMAND
Command ID: 82 (Hex)
Description:
This command is used to perform a Warm Reset on a smart card in the currently selected
connector. If it is available, the ATR from the card is returned.
Request Message Data: None
Response Message Data:
Response Message Result Codes
Code (Hex)
Meaning
00
Success, the command completed without problems.
01
Failure, the command was not able to complete, see CondRpt property for
details. See below for Error/Warning Conditions Template construction.
02
Warning, the command completed, but some problems arose, see CondRpt
property for details. See below for Error/Warning Conditions Template
construction.
Error/Warning Conditions Template Construction – Microprocessor Cards Only
See Error/Warning Conditions Template Construction for the Power Up command.
Example Request:
Field MTYP
APPL
CMND
RC
Byte
1 2 3 4
Value
(Hex)
00 02 82 00
Example Response:
Field MTYP
APPL
CMND
RC
PVAL
Byte
1 2 3 4 5-8
Value (Hex)
40
02
82
00
3B 60 00 00