MagTek IntelliStripe 320 99875168 User Manual
Page 41

Section 5. Smart Card Application
Actual EGT
3D
Dword
1
N/A
Get
This property is the EGT value for the current session. If TC1 was
transmitted in the ATR it was calculated from TC1, otherwise it was
calculated from the Default EGT property.
Actual Class
3E
Binary
1
N/A
Get
This property gives the Class Indicator as reported by the card in the
ATR, or in the absence of a Class Indicator from the card, the default
(Class A only).
Actual Specific
Mode
3F
Boolean
1
N/A
Get
This property gives the specific mode indication as reported by the card in
the ATR, or in the absence of the Specific Mode byte (TA2), the default
value:
FALSE = Negotiable Mode (default)
TRUE = Specific Mode
ATR Map
40
Binary
67
N/A
Get
This property gives a detailed analysis of the ATR as received from the
card. For details see ATR Map Structure.
T=0 Microprocessor Card Setup Properties, used to control the T=0 protocol operations. In order for these properties to influence a card session,
they must be set before the card session begins. Once set, these property values will persist for the current connector until a device reset, or until
they are changed by further property settings.
Name ID
(Hex)
Type Length Reset
Value
Get/Set
Description
Initial T=0 Error
Conditions
Template
51 Binary
4
(Hex)*
0F 00 00
00
Get/Set
Used to define which conditions shall be considered errors when running
with the T=0 protocol. See Error / Warning Condition Templates for
further discussion. See T=0 Error / Warning Conditions for specific
coding.
Initial T=0 Warning
Conditions
Template
52 Binary
4
(Hex)
00 00 00
00
Get/Set
Used to define which conditions shall be considered warnings when
running with the T=0 protocol. See Error / Warning Condition Templates
for further discussion. See T=0 Error / Warning Conditions for specific
coding.
T=0 INS Mask
53
Binary
1
0xFE*
Get/Set
This property defines the mask that is ANDed with an INS byte returned
from the card. If the INS byte, or its inverse, matches the result, the INS
byte is considered to be a valid procedure byte. In the EMV Mode, this
property is set to 0xFF, requiring all bits to match.
T=0 Microprocessor Card Operating Properties, used to control the T=0 protocol operations. Settings of these properties only apply to the current
card session.
35