Get dukpt ksn and counter, Set session id command – MagTek Bluetooth MagneSafe V5 Swipe Reader User Manual
Page 49

Section 5. Communications
41
Get DUKPT KSN and Counter
Command number:
0x09
Description:
This command is used to report the Key Serial Number and Encryption
Counter.
Data structure:
No data is sent with this command.
Response Data:
Offset
Field Name
Description
0
Current Key
Serial Number
This eighty-bit field includes the Initial Key Serial
Number in the leftmost 59 bits and a value for the
Encryption Counter in the rightmost 21 bits.
Result codes:
0x00 (Success)
0x02 (Bad Parameters – the Request Data is not a correct length)
Example Get DUKPT KSN and Counter Request (Hex):
Cmd Num
Data Len
Data
09
00
none
Example Get DUKPT KSN and Counter Response (Hex):
Result Code Data Len
Data
00
0A
FFFF 9876 5432 10E0 0001
SET SESSION ID COMMAND
Command number:
0x0A
Description:
This command is used to set the current Session ID. The new Session ID
stays in effect until one of the following occurs:
1. Another Set Session ID command is received.
2. The reader is powered down.
3. The reader is put into Suspend mode.
The Session ID is used by the host to uniquely identify the present
transaction. Its primary purpose is to prevent replays. After a card is read,
the Session ID will be encrypted, along with the card data, a supplied as
part of the transaction message. The clear text version of this will never
be transmitted.
Data structure:
Request Data:
Offset
Field Name
Description
0
New Session ID
This eight-byte field may contain any value the
application wishes.
Response Data: None
Result codes:
0x00 (Success)
0x02 (Bad Parameters – the Request Data is not a correct length)