Mp flags property – MagTek Bluetooth MagneSafe V5 Swipe Reader User Manual
Page 38

Bluetooth MagneSafe V5 Swipe Reader
30
ICL
0 – Changing the state of the caps lock key will not affect the case of the data
1 – Changing the state of the caps lock key will affect the case of the data
SS
0 – Don’t send Start Sentinel for each track
1 – Send Start Sentinel for each track
ES
0 – Don’t send End Sentinel for each track
1 – Send End Sentinel for each track
LRC 0 – Don’t send LRC for each track
1 – Send LRC for each track
Note that the LRC is the unmodified LRC from the track data. To verify the LRC
the track data needs to be converted back from ASCII to card data format and the
start sentinels that were modified to indicate the card encode type need to be
converted back to their original values.
LC
0 – Send card data as upper case
1 – Send card data as lower case
Er
0x – Don’t send track data if error
11 – Send ‘E’ for each track error
This property is stored in non-volatile memory, so it will persist when the unit is
power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.
MP FLAGS PROPERTY
Property ID:
0x15
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x00
Description:
This property is defined as follows:
0
0
0
0
0
0
0
S
S
0 – MagnePrint Data will NOT be sent
1 – MagnePrint Data will be sent.
This property is used to designate whether or not the MagnePrint data is sent as
part of a message. Setting S to 1 causes the MagnePrint Status and Unencrypted
MagnePrint Data to be sent with each swipe. Setting S to 0 causes these fields to
be omitted from the data. When the fields are omitted, the Programmable Field
Separator that precedes each of these fields will also be omitted.