29
STAY POWERED AFTER SWIPE PROPERTY
Property ID:
0x0E
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x00 (Don’t Stay Powered)
Description:
This property controls whether the reader stays powered after a good swipe.
If the property value is 0x00 (the default), the reader powers down after a
good swipe.
If the property value is 0x01, the reader stays powered after a good swipe. In
this case, the reader may be powered down by the user pressing and holding
the User Switch or it will time out eventually.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.
INTERFACE TYPE PROPERTY
Property ID:
0x10
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
No
Default Value:
3 (Indicates Bluetooth interface)
Description:
The value is a byte that represents the reader’s interface type. It is always set
to 3 indicating this is a Bluetooth reader.
Example Get Interface Type property Request (Hex):
Cmd Num
Data Len
Prp ID
00
01
10
Example Get Interface Type property Response (Hex):
Result Code Data Len
Prp Value
00
01
03
TRACK DATA SEND FLAGS PROPERTY
Property ID:
0x14
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x63
Description:
This property is defined as follows:
ICL
SS
ES
LRC
0
LC
Er
Er