Ss tk3 aamva property, Ss tk2 7bits property, Ss tk3 7bits property – MagTek Bluetooth MagneSafe V5 Swipe Reader User Manual
Page 44

Bluetooth MagneSafe V5 Swipe Reader
36
SS TK3 AAMVA PROPERTY
Property ID:
0x27
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x23 (‘#’)
Description:
This character is sent as the track 3 start sentinel for cards that have track 3
encoded in AAMVA format. If the value is 0 no character is sent. If the
value is in the range 1 – 127 then the equivalent ASCII character will be sent.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.
SS TK2 7BITS PROPERTY
Property ID:
0x28
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x40 (‘@’)
Description:
This character is sent as the track 2 start sentinel for cards that have track 2
encoded in 7 bits per character format. If the value is 0 no character is sent. If
the value is in the range 1 – 127 then the equivalent ASCII character will be
sent.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.
SS TK3 7BITS PROPERTY
Property ID:
0x29
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x26 (‘&’)
Description:
This character is sent as the track 3 start sentinel for cards that have track 3
encoded in 7 bits per character format. If the value is 0 no character is sent. If
the value is in the range 1 – 127 then the equivalent ASCII character will be
sent.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.