beautypg.com

Activity timeout period property, Bluetooth disconnect message property – MagTek Bluetooth MagneSafe V5 Swipe Reader User Manual

Page 36

background image

Bluetooth MagneSafe V5 Swipe Reader


28

ACTIVITY TIMEOUT PERIOD PROPERTY

Property ID:

0x0B

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

120 (0x78) seconds

Description:

This property specifies, in seconds, the minimum amount of time a Bluetooth
reader will operate in the absence of activity. Activity is:

• Swiping and processing of a card.

• Receipt and processing of commands from a Host.

• Briefly pressing the User Switch

When the specified time passes without activity, the reader is powered down.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.


BLUETOOTH DISCONNECT MESSAGE PROPERTY

Property ID:

0x0D

Property Type:

String

Length:

7 bytes

Get Property:

Yes

Set Property:

Yes

Default Value:

The default value is no string with a length of zero.

Description:

This property specifies a string to be used as part of a Bluetooth Disconnect
Message. The message is intended to give the connected host application a
warning that the reader is disconnecting. The full disconnect message consists
of the specified string followed by the character ‘-‘ (hyphen), followed by a
single character Reason Code, followed by a Carriage Return (0x0D)
character. The possible Reason Codes are:

‘T’ = Timeout
‘U’ = User Switch
‘B’ = Battery Low
‘S’ = Card Swipe
‘R’ = Reset command
‘I’ = Interface changed

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.