• This device was designed to be permanently

installed on a building or on a suitable structure.

• When installing the device, comply with all the

national standards.

• The electrical system to which the unit is

connected must be equipped with a bipolar circuit

breaker. The minimum distance between the

contacts must be 3mm (0.1in). The circuit breaker

must be provided with protection against the fault

current towards the ground (differential) and the

overcurrent (magnetothermal, maximum 20A).

• The device must be properly connected to the

earth circuit.

• Any device which could be installed inside the

product must comply with the current safety

standards.

• Before starting any operation, make sure the

power supply is disconnected.

• Installation category (also called Overvoltage

Category) specifies the level of mains voltage

surges that the equipment will be subjected to.

The category depends upon the location of the

equipment, and on any external surge protection

provided. Equipment in an industrial environment,

directly connected to major feeders/short branch

circuits, is subjected to Installation Category III. If

this is the case, a reduction to Installation Category

II is required. This can be achieved by use of an

isolating transformer with an earthed screen

between primary and secondary, or by fitting

listed Surge Protective Devices (SPDs) from live

to neutral and from neutral to earth. Listed SPDs

shall be designed for repeated limiting of transient

voltage surges, suitable rated for operating voltage

and designated as follows: Type 2 (Permanently

connected SPDs intended for installation on the

load side of the service equipment overcurrent

device); Nominal Discharge Current (In) 20kA min.

For example: FERRAZ SHAWMUT, STT2240SPG-CN,

STT2BL240SPG-CN rated 120/240Vac, (In=20kA).

Maximum distance between installation and

reduction is 5m.

4 Identification

4.1 Product description and type

designation

The thermal camera provides vision also in complete

darkness, fog, rain, smoke or for long-range distances.
It is possible to use it for a wide range of high-security

day/night surveillance systems, such as: monitoring

and rescue in the event of a fire, public safety,

along with airport, industrial and environmental

surveillance.
The stainless steel housing allows it to be installed in

environments with highly corrosive external agents,

such as marine, industrial or chemical environments.

4.2 Product markings

See the label attached to the outside of the package.