13.1.4 Environment

Indoor/Outdoor
Installation temperature and operating temperature:

-40°C (-40°F)/+60°C (140°F)
Surge immunity: up to 2 kV line to line, up to 4 kV

between line and earth (EN61000-4-5 level 4)

13.1.5 Certifications

ATEX (EN 60079-0: 2012, EN 60079-1: 2007, EN 60079-

31: 2009)

- b II 2 G Ex d IIB T6 Gb Ta -40°C to +60°C or
- b II 2 G Ex d IIC T6 Gb Ta -20°C to +60°C or Ta

-40°C to +60°C and/or

- b II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C

IECEX (IEC 60079-0: 2011, IEC 60079-1: 2007-04, IEC

60079-31: 2008)

- Ex d IIB T6 Gb Ta -40°C to +60°C or
- Ex d IIC T6 Gb Ta -20°C to +60°C or Ta -40°C to

+60°C and/or

- Ex tb IIIC T85°C Db Ta -40°C to +60°C

IP66/IP67 (EN60529:1991/A1 2001)

13.1.6 Accessories

OCTEX3/4C

Cable gland with gasket EX

3/4" NPT, unarmoured cable

IECEX-ATEX-GOST

OCTEXA3/4C

Cable gland with gasket EX

3/4" NPT, armoured cable

IECEX-ATEX-GOST

OCTEXB3/4C

Barrier cable gland 3/4" NPT,

unarmoured cable IECEX-ATEX-

GOST

OCTEXBA3/4C

Barrier cable gland 3/4" NPT,

armoured cable IECEX-ATEX-

GOST

OCTEX3/4

Cable gland with gasket EX

3/4" NPT, unarmoured cable

ATEX

OCTEXA3/4

Cable gland with gasket EX

3/4" NPT, armoured cable ATEX

13.1.7 Brackets and adapters

MHXWBS

AISI 316L stainless steel wall

bracket

MPXCW

AISI 316L stainless steel corner

adapter module

MPXCOL

AISI 316L stainless steel pole

adapter module

MHXWFWCA

Ball joint in AISI316L stainless

steel