11 special controls – Videotec MAXIMUS MHXT User Manual
Page 30

EN - English - I
nstruc
tions manual
30
SERIAL LINE CONNECTION
Description
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Configuration
Address
OFF
OFF
OFF
OFF
OFF
–
–
–
Reserved
Address
ON
OFF
OFF
OFF
OFF
–
–
–
Address 01
Address
OFF
ON
OFF
OFF
OFF
–
–
–
Address 02
Address
ON
ON
OFF
OFF
OFF
–
–
–
Address 03
…
…
…
…
…
…
–
–
–
…
Address
ON
ON
ON
ON
ON
–
–
–
Address 31
Baud rate
–
–
–
–
–
ON
–
–
9600baud (PELCO D),
38400baud (VIDEOTEC MACRO)
Baud rate
–
–
–
–
–
OFF
–
–
2400baud (PELCO D),
9600baud (VIDEOTEC MACRO)
Protocol
–
–
–
–
–
–
ON
–
PELCO D
Protocol
–
–
–
–
–
–
OFF
–
VIDEOTEC MACRO
Pre-installed module
–
–
–
–
–
–
–
ON
SONY
Pre-installed module
–
–
–
–
–
–
–
OFF
FLIR
Tab. 9
7.3.11 Special controls
SPECIAL CONTROLS
Control
Protocol
PELCO D
VIDEOTEC MACRO
Wiper Start
Save Preset 85
Save Preset 85
Aux 3 ON
Aux 3 ON
Wip+
Wiper Stop
Save Preset 86
Save Preset 86
Aux 3 OFF
Aux 3 OFF
Wip-
Washer Start
Save Preset 87
Save Preset 87
Aux 4 ON
Aux 4 ON
Was+
Washer Stop
Save Preset 97
Save Preset 97
Aux 4 OFF
Aux 4 OFF
Was-
Night Mode on
Save Preset 88
Save Preset 88
Aux 2 ON
Aux 2 ON
Aux+
Night Mode off
Save Preset 89
Save Preset 89
Aux 2 OFF
Aux 2 OFF
Aux-
Reboot
Save Preset 94
Save Preset 94
Tab. 10