11. ATEX certification:
• ATEX certificate number
• Classification for zone type, protection method, temperature class for which this product may be used in
compliance with the ATEX directive
ATEX MARKING
Environment
temperature
Gas
group
Gas marking
Dust marking
-40°C to +60°C
IIB
II 2 G Ex d IIB T6 Gb Ta -40°C to +60°C
II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C
-20°C to +60°C
IIC
II 2 G Ex d IIC T6 Gb Ta -20°C to +60°C
II 2 D Ex tb IIIC T85°C Db Ta -20°C to +60°C
-40°C to +60°C
IIC
II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C
II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C
Tab. 3
12. IECEx certification:
• IECEx certificate number
• Classification for zone type, protection method and temperature class for which this product may be used
in compliance with the IECEx standard
IECEX MARKING
Environment
temperature
Gas
group
Gas marking
Dust marking
-40°C to +60°C
IIB
Ex d IIB T6 Gb Ta -40°C to +60°C
Ex tb IIIC T85°C Db Ta -40°C to +60°C
-20°C to +60°C
IIC
Ex d IIC T6 Gb Ta -20°C to +60°C
Ex tb IIIC T85°C Db Ta -20°C to +60°C
-40°C to +60°C
IIC
Ex d IIC T6 Gb Ta -40°C to +60°C
Ex tb IIIC T85°C Db Ta -40°C to +60°C