02 : potentiometer mappings, 03 : encoder mappings – Electrix Tweaker User Manual
Page 33

6. SysEx Messages
33
Message for Default Settings:
< 240, 00, 01, 106, 01, 01, 00, 01, 00, 02, 00, 03, 00, 04, 00, 05, 00, 06, 00, 07, 00, 08, 00, 09, 00, 10, 00,
11, 00, 12, 00, 13, 00, 14, 00, 15, 00, 16, 00, 17, 00, 18, 00, 19, 00, 20, 00, 21, 00, 22, 00, 23, 00, 24, 00,
25, 00, 26, 00, 27, 00, 28, 00, 29, 00, 30, 00, 31, 00, 32, 00, 33, 00, 34, 00, 35, 00, 36, 00, 37, 00, 38, 00,
39, 00, 40, 00, 41, 00, 42, 00, 43, 00, 44, 00, 45, 00, 46, 00, 47, 00, 48, 00, 49, 00, 50, 247 >
02 : Potentiometer Mappings
This message changes the MIDI mapping of all potentiometers (Channel, Note/CC, and Number).
Total Bytes:
19
Data Bytes:
12
Data Bytes per Pot:
2
1st Data Byte Received:
Mapping Number
2nd Data Byte Received:
Channel Number/ Output Type
Message for Default Settings:
< 240, 00, 01, 106, 01, 02, 00, 51, 00, 52, 00, 53, 00, 54, 00, 55, 247 >
03 : Encoder Mappings
This message changes the MIDI mapping of all encoders (Channel, CC Only, and Number).
Total Bytes:
21
Data Bytes:
14
Data Bytes per Encoder:
2
1st Data Byte Received:
Mapping Number
2nd Data Byte Received:
Channel Number/ Output Type