Win32 implementation restrictions for simple upses, Internal apcupsd actions for simple cables – APC UPS control system User Manual

Page 152

background image

(Shield)--------------------------(4)Chassis GND

Cable 940-0127B

USB(Computer)

RJ45-10(UPS)

_________

____________

| = = = = |

[ oooooooooo ]

|_________|

[____________]

(1)

(4)

(10)

[_]

(1)

+5V(1)-----------(1)+5V

DATA+(2)-----------(9)DATA+
DATA-(3)-----------(10)DATA-

GND(4)-----------(7)Signal GND

(Shield)-----------(4)Chassis GRND

Win32 Implementation Restrictions for Simple UPSes

Due to inadequacies in the Win32 API, it is not possible to set/clear/get all
the serial port line signals. apcupsd can detect: CTS, DSR, RNG, and CD.
It can set and clear: RTS and DTR.

This imposes a few minor restrictions on the functionality of some of the
cables. In particular, LineDown on the Custom Simple cable, and Low
Battery on the 0023A cable are not implemented.

Internal Apcupsd Actions for Simple Cables

This section describes how apcupsd 3.8.5 (March 2002)
treats the serial port line signals for simple cables.

apcaction.c:

condition = power failure detected
cable = CUSTOM_SIMPLE
action = ioctl(TIOCMBIS, DTR)

set DTR (enable power bit?)

apcaction.c:

condition = power back
cable = CUSTOM_SIMPLE
action = ioctl(TIOCMBIC, DTR)

clear DTR (clear power bit)

action = ioctl(TIOCMBIC, ST)

clear ST (TxD)

apcserial.c: