beautypg.com

AMETEK 1746 LDT Interface Card User Manual

Page 21

background image

17

Installation & Programming Manual

Chapter 4: Application Examples

After configuration is complete, the program will copy the position of LDT 1 and LDT 2 from

the input image table into a non-volatile location.

Offset

N7:0

N7:10

N7:20

N7:30

N7:40

0

-32768

-32768

-32768

0

0

1

1

2

2

0

0

2

1111

1

2

0

1

3

1

9300

9272

0

4

2

1

1

0

5

1

1

1

0

6

2

120

240

0

7

0

0

0

0

8

0

0

0

0

9

0

0

0

0

Offset

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

N9:0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

MOV

Move

Source I:1.2

0<

Dest N7:30

0<

MOV

Move

Source I:1.3

0<

Dest N7:31

0<

Move

Source I:1.5

0<

Dest N7:40

0<

MOV

Move

Source I:1.6

0<

Dest N7:41

0<

MOV

END

COPY LDT 1 POSITION (LOW WORD) TO A NON-VOLATILE LOCATION

COPY LDT 1 VELOCITY TO A NON-VOLATILE LOCATION

COPY LDT 2 POSITION (LOW WORD) TO A NON-VOLATILE LOCATION

COPY LDT 2VELOCITY TO A NON-VOLATILE LOCATION

0007

0008

0009

0010

0011