Scrolling help text in display line 3 – Red Lion IAMS User Manual

Page 28

background image

27

[01]

[02]

[03]

[04]

[05]

[06]

[07]

[08]

[09]

[10]

[11]

[12]

[13]

[14]

[15]

[16]

[17]

[18]

[19]

[20]

[21]

[22]

[23]

[24]

[25]

[26]

[27]

[28]

[29]

[30]

[34]

[36]

[37]

[38]

[39]

[41]

[42]

[43]

[44]

[45]

[46]

[47]

[48]

[49]

[50]

[51]

[52]

[53]

[54]

[55]

[56]

[57]

[58]

[59]

[60]

[61]

[62]

Set correct password

Select setup module or NO to store and exit

Select temperature input

Select potentiometer input

Select linear resistance input

Select current input

Select voltage input

Select 0.0­1 V input range

Select 0.2­1 V input range

Select 0­5 V input range

Select 1­5 V input range

Select 0­10 V input range

Select 2­10 V input range

Select 0­20 mA input range

Select 4­20 mA input range

Select 2­wire sensor connection

Select 3­wire sensor connection

Select 4­wire sensor connection

Set resistance value low

Set resistance value high

Select Celsius as temperature unit

Select Fahrenheit as temperature unit

Select TC sensor type

Select Ni sensor type

Select Pt sensor type

Select display unit

Select decimal point position

Set display range low

Set display range high

Set relays in % of input range

Set relays in display units

Select Pt10 as sensor type

Select Pt20 as sensor type

Select Pt50 as sensor type

Select Pt100 as sensor type

Select Pt200 as sensor type

Select Pt250 as sensor type

Select Pt300 as sensor type

Select Pt400 as sensor type

Select Pt500 as sensor type

Select Pt1000 as sensor type

Select Ni50 as sensor type

Select Ni100 as sensor type

Select Ni120 as sensor type

Select Ni1000 as sensor type

Select TC­B as sensor type

Select TC­E as sensor type

Select TC­J as sensor type

Select TC­K as sensor type

Select TC­L as sensor type

Select TC­N as sensor type

Select TC­R as sensor type

Select TC­S as sensor type

Select TC­T as sensor type

Select TC­U as sensor type

Select TC­W3 as sensor type

Select TC­W5 as sensor type

Select TC­Lr as sensor type

Select OFF function ­ relay is permanently off

Select POWER function ­ relay indicates power status OK

Select ERROR function ­ relay indicates sensor error only

Select WINDOW function ­ relay is controlled by 2 setpoints

Select SETPOINT function ­ relay is controlled by 1 setpoint

Select Normally Closed contact

Select Normally Open contact

Set relay setpoint

Activate relay on decreasing signal

Activate relay on increasing signal

Set relay hysteresis

SCroLLIng HeLp text In DISpLAy LIne 3

No error action ­ undefined status at error

Open relay contact at error

Close relay contact at error

Hold relay status at error

Set relay ON delay in seconds

Set relay OFF delay in seconds

Relay contact is Open Inside Window

Relay contact is Closed Inside Window

Set relay window setpoint low

Set relay window setpoint high

Set relay window hysteresis

Open relay contact at error

Close relay contact at erro

Select current as analogue output type

Select voltage as analogue output type

Select 0­20 mA output range

Select 4­20 mA output range

Select S4­20 mA with safety readback

Select 20­0 mA output range

Select 20­4 mA output range

Select S20­4 mA with safety readback

Select no error action ­ output undefined at error

Select downscale at error

Select NAMUR NE43 downscale at error

Select NAMUR NE43 upscale at error

Select 0.0­1 V output range

Select 0.2­1 V output range

Select 0­5 V output range

Select 1­5 V output range

Select 0­10 V output range

Select 2­10 V output range

Select 1­0.0 V output range

Select 1­0.2 V output range

Select 5­0 V output range

Select 5­1 V output range

Select 10­0 V output range

Select 10­2 V output range

Set temperature for analogue output low

Set temperature for analogue output high

Enter Language setup

Enter Password setup

Enter simulation mode

Perform process calibration

Enter display setup

Perform memory operations

Load saved setup into device

Save setup in display front

Adjust LCD contrast

Adjust LCD backlight

Write a 6­character device TAG

Analogue output value is shown in display line 3

Device TAG is shown in display line 3

Calibrate Input low to process value?

Calibrate Input high to process value?

Enable simulation mode?

Set the input simulation value

Relay simulation ­ use ^ and v to toggle relay 1

and 2

Enable password protection?

Set new password

Enable Fastset functionality?

Relay setpoint ­ press OK to save

Relay setpoint ­ Read only

Select language

Use process calibration values?

Set value for low calibration point

Set value for high calibration poin