beautypg.com

Device information, Show device information – Vaisala DPT145 User Manual

Page 34

background image

User's Guide _______________________________________________________________________

34 ___________________________________________________________________ M211371EN-D

Command

Description

SERI [baud p d s]

Show or set the serial interface settings

SMODE [mode]

Show or set startup serial mode:

RUN, STOP, POLL, or MODBUS

SNUM

Display transmitter serial number

TIME

Show transmitter uptime

UNIT [m/n]

Select metric or non-metric units

VERS

Show transmitter firmware version

PNORMT [-100 ... 100] Show or set the temperature for pressure

normalization

MIXRATIO [0 ... 100]

Show or set ratio (%) of SF

6

in the measured

environment

N2MOLW [weight]

Show or set molecular weight of other gas

Device Information

Show Device Information

The ? command outputs a listing of device information.

?

Command ?? is a similar command that is designed to be used if the

transmitter is in POLL mode but its address is unknown. The transmitter

will respond to the ?? command even while in POLL mode. Do not use

the ?? command if you have more than one transmitter on an RS-485

line.

Example:

?

DPT145 1.0.23

Serial number : F4040007

Batch number : F3420050

Module number : F3410001

Sensor number : F1610000

Cal. date : 20110907

Cal. info : Vaisala/HEL

Time : 02:41:01

Serial mode : STOP

Baud P D S : 19200 N 8 1

Output interval: 5 S

Serial delay : 10

Address : 0

Mixing ratio : 100.00% SF6 and 0.00% ideal gas

Ideal gas MolW : 2.8013401e-02 kg/mol