beautypg.com

APC iSCSI SATA II User Manual

Page 13

background image

[13]

RAID Management

The subsystem can implement several different levels of RAID technology. RAID levels
supported by the subsystem are shown below.

RAID Level

Description

Min. Drives

0

Block striping is provide, which yields higher
performance than with individual drives. There is

no redundancy.

1

1

Drives are paired and mirrored. All data is 100%
duplicated on an equivalent drive. Fully

redundant.

2

N-way

mirror

Extension of RAID 1 level. It has N copies of the
disk.

N

3

Data is striped across several physical drives.
Parity protection is used for data redundancy.

3

5

Data is striped across several physical drives.

Parity protection is used for data redundancy.

3

6

Data is striped across several physical drives.
Parity protection is used for data redundancy.

Requires N+2 drives to implement because of
two-dimensional parity scheme

4

0 + 1

Mirroring of the two RAID 0 disk arrays. This

level provides striping and redundancy through
mirroring.

4

10

Striping over the two RAID 1 disk arrays. This

level provides mirroring and redundancy through
striping.

4

JBOD

The abbreviation of “Just a Bunch Of Disks”.

JBOD needs at least one hard drive.

1