beautypg.com

Outback Power Systems GVFX Series Inverter/Charger Installation Manual User Manual

Page 81

background image

79

12 VDC System

DEFAULT

MINIMUM

MAXIMUM

Float Voltage

13.6 VDC

12 VDC

15 VDC

Absorb Voltage

14.4 VDC

13 VDC

16 VDC

EQ Voltage

14.6 VDC

14 VDC

17 VDC

ReFloat

12.5 VDC

12 VDC

13 VDC

LBCO

10.5 VDC

9 VDC

12 VDC

LBCI

12.5 VDC

10 VDC

14 VDC

Sell RE

13 VDC

10 VDC

15 VDC

Gen Alert
Off Set Point

14 VDC

12 VDC

18 VDC

On Set Point

11 VDC

10 VDC

14 VDC

Load Shed Off Set Point

11 VDC

10 VDC

14 VDC

Vent Fan ON Set Point

13 VDC

10 VDC

16 VDC

Diversion ON Set Point

14.6 VDC

12 VDC

16 VDC

Absorb Time

1.0 hours

0.0 hours

24.0 hours

EQ Time

1.0 hours

0.0 hours

24.0 hours

Float Time

1.0 hours

0.0 hours

24.0 hours

AC2/Gen Transfer Delay
(Cycles for AC)

10 cycles

0 cycles

240 cycles

Search

6

0

50

Grid Lower Limit

114 VAC

100 VAC

120 VAC

Grid Upper Limit

140 VAC

130 VAC

140 VAC

Charger OFF/AUTO/ON

AUTO

AUX Output Option

COOL FAN

Gen Alert ON Delay

4 min

0 min

240 min

Gen Alert OFF Delay

9 min

0 min

240 min

Vent Fan OFF Delay

5 min

0 min

30 min

Gen Window Lower Limit

114 VAC

100 VAC

120 VAC

Gen Upper Window Limit

140 VAC

130 VAC

150 VAC

AC1/Grid Transfer Delay

10 Cycles of AC

0 Cycles of AC

240 Cycles of AC

Set AUX Control

AUTO

Search Pulses

8

2

20

Search Pulse Spacing

60 Cycles AC

4 Cycles AC

120 Cycles AC

Stacking Phase

Master

InPut Select

Grid

Charge Rates
Vented 24 & 48 VDC

18 AAC

0 AAC

20 AAC

Sealed 24 & 48 VDC

14 AAC

0 AAC

16 AAC

Grid Input Settings
Set AC Input Size
Grid-Tie

50 Amps

5 Amps

60 Amps

Gen Input Settings
Grid-Tie

30 Amps

5 Amps

60 Amps

FX Default Values (subject to change with FX upgrades)

C

or

rec

tion

F

ac

tor

•24VDC:

M

ultiply

12VDC

values

b

y

2

•48VDC:

M

ultiply

12VDC

values

b

y

4

This manual is related to the following products: