beautypg.com

Important, Injector signal wires – GReddy e-Manage Ultimate Installation Manual User Manual

Page 17

background image

16

10.

Injector Signal Wires

# E

Ч Ч

Ч

When changing I/J CH
Example: Changing group injection to sequential injection

How to connect
• Connect the necessary I/J CH OUT wires to
the Connector C.
• The I/J CH Setting must be configured with
PC before starting the engine.
• Confirm the injector wiring to match the
injection method.

Sub Injector Wiring
When using the CH for sub injectors

Connect to
desired CH

When using high resistance injectors

When using low resistance injectors

Dropping
Resistor

When using low resistance injectors, dropping resistors are required to control the injectors.

Important

Female connector

Male connector

Splice

ECU
(Engine Control Unit)

Light Blue/Red (I/J CH- 6 IN)

Pink/Red (I/J CH- 5 IN)

Purple/Red (I/J CH- 4 IN)

Black/Red (I/J Ground)

Blue/Red (I/J CH- 1 IN)

Orange/Red (I/J CH- 2 IN)

Yellow/Red (I/J CH- 3 IN)

Blue/Red (I/J CH- 1 IN)

Orange/Red (I/J CH- 2 IN)

Yellow/Red (I/J CH- 3 IN)

Injector

Connector B

Connector B

Connector C