Finishing the Sensor Connections to the Station

1. Secure sensor cables within the cable

clamps located next to the grommets.

2. Secure the cable clamps using the by

screwing them to the cable clamp
mounts inside the housing near the
grommets.

3. To prevent fraying or cutting of

cables, secure them so they will not whip about in
the wind. Secure a cable to a metal pole by wrap-
ping electrical tape around them both. Make sure
cables are secure by placing clips or ties approxi-
mately every 3 – 5' (1 – 1.6 m).

Note:

Do not use metal staples or a staple gun to secure cables. Metal staples — especially when
installed with a staple gun — have a tendency to cut the cables.

Mounting the Sensor Against a Wooden Surface

To mount the sensor against a
wooden surface, secure the sensor to
the surface using the #8 wood
screws as shown below.

Cable Clamp
Mount

Leaf Wetness

Sensor Cable

Rubber

Grommets

SENSOR

SENSOR

INTERFACE

INTERFACE

MODULE

MODULE

Cable Clamp

Cable Clamp
Screw

Temperature

Moisture

1 2 3 4 1 2 3 4

Soil Moisture

Sensor Cable

Temperature

Probe Cable

Securing Sensor Cables

Cable Clip

Cable Tie

Securing Cables with Clips and Ties