beautypg.com

Rmc 7150, 14” short depth rack server – Acnodes RMC 7150 User Manual

Page 25

background image

14628 Central Blvd,

Chino, CA91710

tel:909.597.7588, fax:909.597.1939

© Copyright 2011 Acnodes, Inc.

All rights reserved. Product description and product specifications

are subject to change without notice. For latest product information,

please visit Acnodes’ web site at www.acnodes.com.

RMC 7150

14” short depth rack server

25

Removing the Heatsink

1. Power down the system and unplug the power cord

from the power supply.

2. Disconnect the heatsink fan’s wires from the fan header.

3. Using a screwdriver, loosen and remove the heatsink

screws from the serverboard in the sequence as shows in the

previous section (#1 and #2 followed by #3 and #4.

4. Hold the heatsink as showin in the picture on the right and

gently wiggle it to loosen it from the CPU.

5. Once the heatsink is loose, remove it from the CPU

socket.

6. To reinstall the heatsink, clean the surface of the CPU and

the heatsink to get rid of the old thermal grease. Reapply the

proper amount of thermal grease to the surface of the CPU

then reinstall the heatsink.