Setting the host mode, Setting the host mode 36 – HP LUN Configuration Manager XP Software User Manual
Page 36
36
HP StorageWorks LUN Configuration Manager XP: user’s guide
Setting the host mode
LUN Configuration Manager XP allows you to set the host mode for each
SCSI port on the disk array. The following table describes each host mode.
Host
Mode
FWD
Description
Host
Mode
Ultra
Description
0x00
Standard mode–
fast-wide differential SCSI (FWD)
Fibre Channel (FC)
Linux, SGI IRIX host mode
0x10
Standard mode and Ultra SCSI mode
0x01
IBM-7135 host mode (FWD)
0x11
IBM-7135 host mode and Ultra SCSI
mode
0x02
NCR host mode (FWD)
0x12
NCR host mode and Ultra SCSI mode
0x03
HP-UX Extension host mode
0x13
Not used
0x04
Sequent host mode (FWD)
0x14
Sequent host mode and Ultra SCSI mode
0x05
Open VMS host mode
0x15
Not used
0x07
Tru64 host mode
0x08
HP-UX mode (FWD or FC)
Queue depth: 1024
LUNs per port: 120
HP NetServer with HP host bus adapters
(HBAs)
0x18
HP-UX and Ultra SCSI mode
0x09
VxVM-DMP (FWD)
0x19
VxVM-DMP and Ultra SCSI mode
0x0A
Netware host (FWD)
0x1A
Netware host and Ultra SCSI mode
0x0C
PC Server, Windows NT/2000,
MS Cluster Server (Wolfpack)–Non-HP
HBAs (FWD)
0x1C
MS Cluster Server (Wolfpack) and Ultra
SCSI mode–Non-HP HBAs
0x0D
I/O TRACE mode
0x0F
AIX host mode
Others
Not used