beautypg.com

HP LUN Configuration Manager XP Software User Manual

Page 29

background image

Operation

29

4. Paths can be defined individually (individual mode) or in a group (bulk

mode).

(Individual Mode) Select PORT, SCSI ID, and LUN one by one for
each LDEV ID.

(Bulk Mode) Select the desired CU number; then select the SCSI ports,
TIDs, and LUN IDs you want to assign; and then select the corre-
sponding LDEV IDs. Select the first LDEV ID and LUN Manager
assigns the remaining paths sequentially, or select the specific LDEV
IDs you want to assign.

A bulk mode operation will fail if the number of LUNs defined
exceeds the number of LDEVs available.

To calculate the number of LUNs to select, multiply the number of
selected ports, the number of selected SCSI TIDs, and the number of
selected LUN IDs. For example, if you select one port, four SCSI
TIDs, and two LUN IDs, you must select eight LUNs (1

Ч 4 Ч 2 = 8).