Controller failure in a single-controller configuration

51

Is the power supply Input Power Source LED off?

Is the power supply Voltage/Fan Fault/Service Required LED amber?

Controller failure in a single-controller configuration

Cache memory is flushed to CompactFlash in the case of a controller failure or power loss. During the write

to CompactFlash process, only the components needed to write the cache to the CompactFlash are

powered by the supercapacitor. This process typically takes 60 seconds per 1 Gbyte of cache. After the

cache is copied to CompactFlash, the remaining power left in the supercapacitor is used to refresh the

cache memory. While the cache is being maintained by the supercapacitor, the Cache Status LED flashes

at a rate of 1/10 second on and 9/10 second off.

IMPORTANT:

Transportable cache only applies to single-controller configurations. In dual controller

configurations, there is no need to transport cache from a failed controller to a replacement controller

because the cache is duplicated between the peer controllers (subject to volume write optimization setting).

Answer

Possible reasons

Actions

No

System functioning properly.

No action required.

Yes

The power supply is not receiving

adequate power.

Verify that the power cord is properly connected and check

the power source to which it connects.

Check that the power supply FRU is firmly locked into

position.

In the SMU, check the event log for specific information

regarding the fault; follow any Recommended Actions.

If the above action does not resolve the fault, isolate the

fault, and contact an authorized service provider for

assistance.

Table 12

Diagnostics LED status: Rear panel power supply “Input Power Source”

Answer

Possible reasons

Actions

No

System functioning properly.

No action required.

Yes

The power supply unit or a fan is

operating at an unacceptable

voltage/RPM level, or has failed.

When isolating faults in the power supply, remember that the

fans in both modules receive power through a common bus on

the midplane, so if a power supply unit fails, the fans continue to

operate normally.

Check that the power supply FRU is firmly locked into

position.

Check that the power cable is connected to a power source.

Check that the power cable is connected to the power

supply module.

Table 13

Diagnostics LED status: Rear panel power supply: “Voltage/Fan Fault/Service Required”