Obtaining IP values
39
• Linux customers should enter the command syntax provided in
"Preparing a Linux computer before
cabling to the CLI port" (page 37)
.
• Windows customers should locate the downloaded device driver described in
device driver for Windows computers" (page 37)
, and follow the instructions provided for proper
installation.
4.
Start and configure a terminal emulator, such as HyperTerminal or VT-100, using the display settings in
(page 39) and the connection settings in
(page 39) (also, see the note following this
procedure).
.
1
Your server or laptop configuration determines which COM port is used for Disk Array USB Port.
2
Verify the appropriate COM port for use with the CLI.
5.
In the terminal emulator, connect to controller A.
6.
Press Enter to display the CLI prompt (#).
The CLI displays the system version, MC version, and login prompt:
a. At the login prompt, enter the default user manage.
b. Enter the default password !manage.
If the default user or password—or both—have been changed for security reasons, enter the secure
login credentials instead of the defaults shown above.
7.
At the prompt, type the following command to set the values you obtained in
for each network
port, first for controller A and then for controller B:
set network-parameters ip
address netmask netmask gateway gateway controller a|b
where:
•
address
is the IP address of the controller
•
netmask
is the subnet mask
•
gateway
is the IP address of the subnet router
• a|b specifies the controller whose network parameters you are setting
For example:
# set network-parameters ip 192.168.0.10 netmask 255.255.255.0 gateway
192.168.0.1 controller a
# set network-parameters ip 192.168.0.11 netmask 255.255.255.0 gateway
192.168.0.1 controller b
8.
Type the following command to verify the new IP addresses:
show network-parameters
Table 2 Terminal emulator display settings
Parameter
Value
Terminal emulation mode
VT-100 or ANSI (for color support)
Font
Terminal
Translations
None
Columns
80
Table 3 Terminal emulator connection settings
Parameter
Value
Connector
COM3 (for example)
1,2
Baud rate
115,200
Data bits
8
Parity
None
Stop bits
1
Flow control
None