Smart Array Controller Status

Transfers/Sec—The number of requests between the server and this IDE Smart Array controller each
second

MBytes/Sec—The sum of all megabytes transferred (read and written) between the server and this
Smart Array controller each second

Millisec/Transfer—The average time for each request to complete

Queue Length—The average number of concurrent requests between the server and this Smart Array
controller, including transfers currently being serviced and transfers waiting for service, regardless of
where the request is waiting (drive or controller)

Smart Array controller performance is based on the performance of the SCSI disks attached to the controller
and the SCSI buses used to attach the drives to the controller.

Smart Array Controller Inventory

Controller Configuration

The controller identification, including controller model and PCI slot (if applicable)


The supported and negotiated PCI protocols (bus speed)

The controller cache configuration

Number of hard disks attached to the controller

Number of SCSI ports currently in use on the controller

Number of arrays on the controller

Number of array logical drives defined on the controller

Windows/Linux Physical Disks—Lists the physical disk drives and identifies each drive SCSI ID, drive
letter, and associated Smart Array controller

SCSI adapter

The following information is provided for a SCSI adapter.

SCSI Adapter Status

Transfers/Sec—The number of requests between the server and this SCSI adapter each second

MBytes/Sec—The average number of megabytes transferred (read and written) between the server
and this SCSI adapter each second

Millisec/Transfer—The average time for each request to complete

Queue Length—The average number of concurrent requests between the server and this SCSI adapter,
including transfers currently being serviced and transfers waiting for service, regardless of where the
request is waiting (drive or adapter)

SCSI adapter performance is based on the performance of the SCSI disks attached to the adapter and the
SCSI buses used to attach the disks to the adapter.

SCSI Adapter Inventory

Identifies the supported and negotiated PCI protocol (bus speed) used by the SCSI adapter

Provides the number of SCSI drives configured on the adapter

Provides the number of SCSI ports used

Windows/Linux Physical Disks—Lists the physical disk drives and identifies each drive SCSI ID, drive
letter, and associated SCSI adapter

Drive array

The following information is provided for a drive array.

SCSI adapter

55