beautypg.com

HP Insight Control User Manual

Page 44

background image

Solution

Occurs when

Issue

Add the performance management menu
manually.

To manually add the performance
management menu, perform either of the
following procedures:

From the command line, enter: mxtool
–a –f “path>:\Insight Control
performance
management\PMPTools.xml”

Execute the command
mxconfigrefresh

from the command

line interface.

Copy PMPTools.xml from installation path>:\Insight
Control performance
management\

to

installation path>:\Systems
Insight Manager\Setup

.

Execute the command
mxconfigrefresh

from the command

line interface.

The PMPTools.xml file is not executed
properly during HP SIM and performance
management integration.

After the performance management
installation, the performance management
menu might not appear on the HP SIM
console.

Note the name used in the browser window.
Verify that the name resolves on the network
and that it is not being affected by any proxy
settings in the browser.

HP SIM CMS name link is not resolved
correctly on the network.

The error message Page Not Found
appears when launching performance
management from the HP SIM menu.

Performance management licensing and monitoring administration issues

The following table describes issues and solutions that can be associated with licensing and monitoring
administration.

Table 6-3 Performance management license administration issues

Solution

Occurs when

Issue

To reactivate the appropriate Current User
access level rights after a session has
expired:

1.

Close the Unknown Performance status,
Error Performance Status, or Monitoring
Administration

page.

2.

Launch the page again by clicking the
appropriate icon in the PF column of the
HP Insight Control console or by selecting
the page from the HP Insight Control
console toolbar.

The Unknown Performance status, Error
Performance status

, or Monitoring

Administration

page was left unattended

and idle for 15 minutes or more. The
session has expired, and performance
management set the Current User level to
Anonymous as a security precaution.

While logged in as Administrator, access
to functions from the Monitoring
Administration

page is lost and one of

the following error messages appears:

The Current User must have
'administrator' or 'operator'
rights enabled in order to
access performance management
administration functions.

The Current User must have
'administrator' rights
enabled in order to access
performance management
licensing functions.

44