Advanced topics 21

Command-line argument Description

Failed dependencies are not reported to the user when using the /s[ilent]

argument. To verify failed dependencies, remove the /s[ilent] argument,

reissue the command line, and then the HP SUM GUI appears.

/allow_update_to_bun

dle

This argument is a filter switch and enables the user to install newer versions of

components defined in a PSP or firmware bundle.

This argument enables these components to replace the older versions of the
same component that might have shipped with the bundles.

/allow_non_bundle_co

mponents

This argument is a filter switch and enables the user to install components that are

not included in the bundle but reside in the directory with the components in the
bundle.

/b[undle]

or

This argument specifies the bundles to install. Bundles to install can be specified
with or without the /b[undle] argument.

If using the /b[undle] argument, then only one bundle can be specified

with the argument. However, multiple /b arguments and bundles can be

specified on the same line.

If the /b[undle] argument is not used, then multiple bundles can be

specified at the same time, but the bundles need to be separated by a blank

and listed after all the arguments on the command line.

Multiple components and bundles can be specified on the same command line.

When mixing components and bundles on the command line, the filter switches
control what components and bundles are installed.

/express_install

This argument starts express install (for local host only). HP SUM performs

discovery, install, or exit without user interaction. The user can cancel or

terminate HP SUM.

/use_snmp

This argument specifies that components, which use SNMP protocol, are

available to be selected for installation. These components are available for
selection by default. When the /use_snmp argument is used, and the

/use_wmi argument is not, the WMI components are optional.

/use_location

“file_share”

This argument specifies a directory or file share that contains the PSP and

components for use with HP SUM. The file_share format must be a mapped file

share and not in UNC format.
If you do not specify this argument, the directory containing hpsum.exe or HP

SUM is used by default. The logged-in account must have access to this location.
The /user and /passwd arguments do not have any effect when attempting to

access the file share. You can use those arguments only when connecting to a

target system.

/use_web

This argument specifies that the check-box for Check ftp.hp.com on the Source

Selection screen is to be selected. This enables components to be retrieved from

hp.com and to be used in the list of possible updates.

/use_proxy

server>

This argument enables the inclusion of a proxy server (and port number) to access
the HP FTP site (

ftp://ftp.hp.com

). This argument must be used with /use_web.

For example, /use_web /use_proxy <1.22.33.44:80>

/proxy_script

script>

This argument enables the inclusion of a proxy script to access the HP FTP site
(

ftp://ftp.hp.com

). This argument must be used with /use_web. For example,

/use_web /proxy_script

/use_d[ownloaded]

This argument specifies that the check box for Include components previously
downloaded from HP.com on the Source Selection screen is to be selected. This

enables those previously downloaded components to be included in the list of

possible updates.

/tpmbypass or

/ignore_tpm

This argument specifies that if a Trusted Platform Module (TPM) is enabled, then
the warning message can be ignored and component installation continues.