HP ProLiant Support Pack User Manual
Page 18
Deploying PSPs 18
4.
Change to the /compaq/csp/linux directory.
5.
Execute the ./hpsum command to install the Linux HP PSP.
Deploying PSP with HP SUM:
1.
In the Source Selection screen, verify that the directory path in the Directory field has the location of the
smart components in the PSP and then select Start Inventory. HP SUM performs an inventory of the
available updates and checks the local system to see what hardware and software is installed. After the
inventory and discovery processes finish, the Select Installation Hosts screen appears.
2.
Select either the local host or one (or more) remote hosts for PSP deployment. The Select bundle filter
screen displays the PSP bundle information.
3.
Select the bundle and the appropriate filter options. For remote deployments, additional screens enable
you to update information on a per-host basis.
4.
After selecting the bundle for all hosts being updated, access the Select Items to be Installed screen to
complete the following tasks:
a.
Select the components to be installed.
b.
Review failed dependencies before installation.
c.
Review the revision history of the components.
5.
Click Install to proceed with the installation. After installation completes, the Installation Results screen
appears.
6.
If any components did not install successfully, complete the following steps:
a.
Review the installation logs for information about any failures.
b.
Exit HP SUM.
c.
Make the required update to the environment.
d.
Restart installation of the PSP.
For more information, see the HP Smart Update Manager User Guide