beautypg.com

User – HP Integrity BL870c i2 Server-Blade User Manual

Page 69

background image

Command line 69

Item

Description

UplinkSetName

(required)

The name of an existing shared uplink set to modify

Properties

Name (optional)

The new name of the shared uplink set

ConnectionMode

(optional)

Specifies the connection type that is formed when multiple ports are added to
the uplinkset. Valid values include "Auto" and "Failover". The default value is

"Auto".

Examples

->set uplinkset Blue Name=Red
Changes the name of an shared uplink set from "Blue" to "Red"

->set uplinkset Blue connectionMode=Failover
Changes the connection mode of the uplink set

Item

Description

show uplinkset

Display shared uplink configurations.

Syntax

show uplinkset [ | *]

Parameter

UplinkSetName

(optional)

Name of an existing uplink port set. "*" displays a detailed view of all the

uplink port sets. If not specified, summary of all uplink port sets will be
displayed.

Examples

->show uplinkset
Displays a summary listing of all uplink sets

->show uplinkset *
Displays detailed information for all shared uplink sets

->show uplinkset MyNetwork
Displays detailed information for a specific shared uplink set

user

Manage local domain user configurations.
Supported actions: add, help, remove, set, show

Item

Description

add user

Create a new user and add it to the Virtual Connect Manager database.

Syntax

add user Password= [FullName=

Name>] [ContactInfo=]

[Enabled=]

[Privileges=]

Parameter

UserName

(required)

The name of the new user to add. The username must be unique within the

domain.

Properties

This manual is related to the following products: