Fc-connection – HP Integrity BL870c i2 Server-Blade User Manual
Page 29
Command line 29
Item
Description
Displays detailed information for all FC SAN fabrics
->show fabric SAN_5
Displays detailed information for a specific FC SAN fabric
fc-connection
Manage Fibre Channel SAN connections.
Supported actions: add, help, remove, set, show
Item
Description
add fc-connection
Add a new FC SAN connection to an existing server profile.
Syntax
add fc-connection
[Speed=
[AddressType=
[PortWWN=
Parameter
ProfileName
(required)
The name of an existing profile to which the new connection is added
Properties
Fabric (optional)
The name of an existing fabric to associate with the connection. If the fabric
name is not specified, then the connection is marked as “Unassigned” but
associated with a specific bay.
Speed (optional)
The port speed of the connection port. Valid values include "Auto", "1Gb",
"2Gb", "4Gb", "8Gb", and "Disabled". If not specified, then the default
port speed is set to "Auto".
Speed restrictions:
For the HP 4Gb VC-FC Module and HP Virtual Connect 4Gb FC Module,
supported speed values include "Auto","1Gb","2Gb", and "4Gb", and
"Disabled". If the value is set to 8Gb, the speed is auto-negotiated by Virtual
Connect.
AddressType
(optional)
The source of WWN address assignments to be used during the creation of
the new connection. If not specified, the default is the domain default. If
"UserDefined" is specified, then both a Port WWN and Node WWN must
also be specified. Valid values include "Factory-Default" and "User-Defined".
PortWWN (required if
AddressType is User-
Defined)
The user-defined Port WWN address to use for the connection. This property
is required if the AddressType specified is "User-Defined". The PortWWN
must be an unused WWN address.
NodeWWN (required if
AddressType is User-
Defined)
The user-defined Node WWN address to use for the connection. This
property is required if the AddressType specified is "User-Defined". The
NodeWWN must be an unused WWN address.
Examples
->add fc-connection MyNewProfile Fabric=SAN_5
Adds a new FC SAN fabric connection to a profile
->add fc-connection MyNewProfile Fabric=SomeFabric
Speed=4Gb
Adds a new FC SAN connection and configures the port speed