Command line 46

Item

Description

configured properly before port monitoring can be enabled.

AnalyzerPort

(optional)

The uplink port used for monitoring network traffic. The format of the network

analyzer port is ::.

If the enclosure ID is not specified, the default enclosure is the local enclosure.

Speed (optional)

The port speed for the network analyzer port. Valid values include "Auto",

"10Mb", "100Mb", "1Gb", "10Gb", and "Disabled". The default value is
"Auto".
If there is no connector present on the analyzer port, only "Auto" and
"Disabled" can be configured as a possible speed. Speed restrictions apply.

Duplex (optional)

The port duplex mode of the network analyzer port. Valid values include
"Auto", "Half", and "Full". The default value is "Auto".

MonitorPort

(required if the

Direction property

is being modified)

The server port to be monitored. The format of the monitored port is
::.
If the enclosure ID is not specified, the default enclosure is the local enclosure
where the domain resides.

Direction

(optional)

The direction of network traffic on the port being monitored. Valid values
include "ToServer", "FromServer", and "Both".

Examples

->set port-monitor AnalyzerPort=enc0:3:1 Speed=1Gb

Duplex=half
Modifies network analyzer uplink port properties

->set port-monitor MonitorPort=enc0:1:6

Direction=ToServer
Modifies a monitored server port

->set port-monitor Enabled=true
Enables port monitoring

->set port-monitor Enabled=false
Disables port monitoring

Item

Description

show port-monitor

Display the Virtual Connect port monitor configuration.

Syntax

show port-monitor

Example

->show port-monitor
Displays the port monitor configuration

profile

Manage server profiles.
Supported actions: add, assign, help, remove, set, show, unassign

Item

Description

add profile

Create a new server profile. After the profile has been created, the profile can

then be configured using the "set" subcommand, and the additional network,
fabric, and FCoE connections can also be added. The server profile can also be

This manual is related to the following products: