Item
Description
BootPort (optional)
The target WWPN of the controller interface on the Fibre Channel storage
target. The port name is a 64-bit identifier in the format
NN:NN:NN:NN:NN:NN:NN:NN, where N is a hexadecimal number.
BootLun (optional)
The LUN of the volume used for SAN boot. Valid values include an integer
from 0 to 255 or 16 hex digits (HP-UX only).
Examples
->set fc-connection MyProfile 1 Fabric=SAN_5
Changes the fabric of an FC SAN fabric connection
->set fc-connection RedProfile 2 Fabric=""
Sets a FC SAN fabric connection to "Unassigned"
->set fc-connection BlueProfile 1 Fabric=SAN_7
Changes the FC SAN fabric of an FC SAN connection
->set fc-connection BlueProfile 1 Speed=4Gb
Changes the port speed of an FC SAN connection
->set fc-connection BlueProfile 1 BootPriority=Primary
BootPort=50:06:0B:00:00:C2:62:00 BootLun=5
Changes the SAN boot priority and sets additional boot parameters
Item
Description
show fc-connection
Display the FC SAN connections associated with the server profiles.
Syntax
show fc-connection [
Parameter
ConnectionID
(optional)
The ID of an existing FC SAN connection. The ID format is
SAN connections of a profile. '*' displays all the FC SAN connections
existing in the domain.
Examples
->show fc-connection
Displays all FC SAN connections existing in the domain
->show fc-connection Profile1:*
Displays FC SAN connections of profile Profile1
->show fc-connection Profile1:1
Displays a specific FC SAN connection of profile Profile1
firmware
Display the Virtual Connection firmware version.
Support actions: help, show
show firmware
Display the firmware information for all interconnect modules in the domain.
Syntax
show firmware