Snmp – HP Integrity BL870c i2 Server-Blade User Manual
Page 56
Command line 56
Item
Description
Modifies the VLAN ID of an existing server port network mapping
->set server-port-map MyProfile:1 Network1 Untagged=true
Modifies the existing server port network mapping to handle untagged packets
Item
Description
show server-port-
map
Display a server port network mapping. This command cannot be used if the
domain setting, VLanTagControl, is set to "Tunnel".
Syntax
show server-port-map [
Parameter
ConnectionID
(optional)
The reference ID of an existing enet-connection associated with a profile and a
server port. The format of the ConnectionId is
Examples
->show server-port-map
Lists all the server port mappings
->show server-port-map MyProfile:1
Displays the server port mapping for a profile
->show server-port-map *
Displays detailed output of all the server port mappings
snmp
View and modify the SNMP configuration for VC-Enet and VC-FC modules, and add, modify, and remove
SNMP trap configurations related to trap destinations.
Supported actions: set, show, help
Item
Description
set snmp
Modify the VC SNMP configuration.
Syntax
set snmp
[SystemContact=
[SmisEnabled=
Parameter
Type (required)
Indicates which SNMP configuration to modify. Valid values include "Enet" and
"FC".
Properties
ReadCommunity
(optional)
Read-Only Community String for the SNMP configuration. The default value is
"public". If the type is "Enet", the maximum length of the read community string
is 39 characters. If the type is FC, the maximum length is 12 characters.
SystemContact
(optional)
SNMP system contact information.
Enabled (optional) Enables or disables the SNMP agent. The default value is "true". Valid values
include "true" or "false".
SmisEnabled
(optional)
Enables or disables SMIS. This property is valid only for VC-FC modules. The
default value is "false". Valid values include "true" or "false".