Command line 25
Item
Description
address>] [MacEnd= Default|User-Defined>] [WwnStart= [WwnEnd= User-Defined>] [ServerIdStart= [ServerIdEnd= Option quiet This option suppresses user confirmation prompts and is useful when scripting Properties UserName (optional) A valid external manager user name. The user name can be identified using the MacType (optional) The type of MAC address source to use for assignment. Valid values include "Factory-Default" and "User-Defined". MacStart (required if the MacType is User-Defined) The starting MAC address in a custom user-defined range. This property is only valid if the MacType is set to "User-Defined". MacEnd (required if the MacType is User-Defined) The ending MAC address in a custom user-defined range. This property is only valid if the MacType is set to "User-Defined". WwnType (optional) The type of WWN address source to use for assignment. Valid values include "Factory-Default" and "User-Defined". WwnStart (required if the WwnType is User-Defined) The starting WWN address in a custom user-defined range WwnEnd (required if the WwnType is User-Defined) The ending WWN address in a custom user-defined range ServerIdType (optional) The type of the virtual serial number source. When server profiles are created, source. Valid values include "Factory-Default" and "User-Defined". ServerIdStart (required if Type is User-Defined) The starting serial number in a user-defined range. This property is only valid for user-defined serial number types. ServerIdEnd (required if Type is User-Defined) The ending serial number in a user-defined range. This property is only valid for Examples ->remove external-manager UserName=A17005068 ->remove external-manager macType=Factory-Default wwnType=Factory-Default serverIdType=Factory-Default ->remove external-manager username=A1010345 macType=Factory-Default wwnType=Factory-Default serverIdType=Factory-Default ->remove external-manager username=A19216811 mactype=User-Defined MacStart=00-17-A4-77-00-00 MacEnd=00-17-A4-77-03-FF wwnType=User-Defined WwnStart=50:06:0B:00:00:C2:62:00 WwnEnd=50:06:0B:00:00:C2:65:FF serverIdType=User-Defined serverIdStart=VCX0000000 serverIdEnd=VCX00000ZZ
operations.
show external-manager command.
the virtual serial numbers and UUID values are allocated from the specified pool
user-defined serial number types.
Removes only the external management control of the VC Manager
Releases only the profile control
Removes the external manager and releases the profile control