Internal tests:running, Tests:internal, Internal tests:used by service – HP Surestore 320ex Optical Jukebox User Manual
Page 60: Internal tests:listing of, Ready, The optical jukebox can run self-diagnostic tests, Caution some of the internal diagnostic tests of t, In almost all cases, these tests should be run onl, Instructions for running internal tests are includ, Start with
3-26
Chapter 3
Operating the Jukebox
Running an Internal Test
Running an Internal Test
READY
>
ADMIN *
>
TEST *
The optical jukebox can run self-diagnostic tests. See the Caution note below.
CAUTION
Some of the internal diagnostic tests of this jukebox can corrupt your file system if
not properly completed (for example, disks can be placed in unexpected locations).
In almost all cases, these tests should be run only by authorized service personnel.
Service, however, may request that you run specific tests to provide information
before they come to your site. The descriptions of these tests are included in this
manual only for your information.
Instructions for running internal tests are included in this guide to help you run tests
if requested by service. There is a possibility you may run one test as a result of
troubleshooting; this test is “
INIT ELEM STATUS
.”
Start with
READY
in the display.
1. Press
NEXT
until
ADMIN *
displays.
2. Enter the administration password.
Instructions for entering this password are in “Entering the Administration
Menu Password” previously in this chapter.
3.
TEST *
displays. Press
ENTER
.
4. Press
NEXT
until the name of the test you wish to run displays and then press
ENTER
to start the test.
NOTE
You may press
CANCEL
at any time to abort a test. A delay may occur while the
current test loop completes.