Suggested action – HP Virtual Connect Enterprise Manager Software User Manual
Page 65

Suggested action
Reboot the server and then reinstall PSP manually.
Destination server still shows server migration UI but server migration Wizard shows
migration completed
After the migration, server migration losses connectivity to Hyper-V host, which causes server
migration to fail to eject the boot CD and reboot the VM. If server migration is unable to connect
Hyper-V host, then reboot using the destination agent. In this case, server migration will be unable
to eject the boot CD and as a result, after the reboot, the VM will boot back into the boot CD. This
issue is specific to Microsoft Hyper-V VM.
Suggested action
You must manually eject the virtual boot CD from the VM and reboot the VM.
Operating system is not booting up on the destination server with SAN disks
After you perform a successful P2P migration of SLES 11 SP1 32-bit operating system on SAN
disks with Brocade or QLogic Fibre Channel HBA as the primary boot controller, operating system
does not boot up on the destination server.
Suggested action
Before you migrate any Linux distribution to destination server with SAN storage, ensure that the
RPM package containing firmware files (such as brocade-firmware-
and qlogic-firmware-
ql2xxx-firmware-
on RHEL OS) for the target SAN FC HBA are
installed on the source server from the OS installation media.
Error displayed for missing file system while booting migrated Linux OS on the
destination server
When you migrate a file system to the destination server multiple times, the multiple file systems
containing the same UUID are created.
Suggested action
Ensure that multi-path is configured on the source server. If multi-path is not configured, ensure that
the file systems that are being migrated do not have the same UUID.
Logical drives of HP Smart Array B110i SATA RAID Controller are removed
After a successful X2P migration of Windows Server 2008 OS, the logical drives of HP Smart
Array B110i SATA RAID Controller are removed.
Suggested action
When the logical drives are removed, you must re-create the exact logical drives using ACU or
ORCA on the destination server after migration.
Post-migration