Environmental specification, Vibration and shock tolerance – HP Surestore DLT 80 Tape Drive User Manual
Page 40

Product Specifications and Ordering Information
Product Specification
A-3
Environmental Specification
See page 3-5 for advice on using and storing cartridges.
Operating Limits
Non-operating Limits
Vibration and Shock Tolerance
Operating Vibration
Overstress
Operating Shock
Temperature: 10°C to 40° C (50°F to 104°F)
Humidity:
20% to 80% non-condensing
Altitude:
0 m to 9 km (0 to 30,000 ft)
Temperature:
−
40°C to 66° C (
−
40°F to 151°F)
Humidity:
10% to 95% non-condensing
Altitude:
0 m to 15 km (0 to 50,000 ft)
Vibration Type
Sine
Sweep
Frequency Range:
5–500–5 Hz
Upward and downward
Acceleration Level: 0.25g
0.010” DA
22 to 500 Hz
5 to 22 Hz (crossover)
Application:
X, Y and Z axes
Sweep rate: 1 octave per minute
Vibration Type
Sine
Sweep
Frequency Range:
5–500–5 Hz
Upward and downward
Acceleration Level: 0.50g
0.010” DA
26.1 to 500 Hz
5 to 26.1 Hz (crossover)
Application:
Vertical axis (top/bottom) Sweep rate: 1 octave per minute
Pulse Shape:
½ sine pulse
Peak Acceleration:
10g
Duration:
10 ms
Application:
X, Y and Z axes, once in each axis
dlt-m.book Page 3 Thursday, May 4, 2000 3:52 PM
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)