Table 25 RAID Manager errors related to manual migration plans (continued)
Required Action
Message
Error Code
(SSB2)
Release the setting of Cache Residency, and then
migrate the volume.
Cache Residency is set on the migration target
volume.
238A
None. LUSE volumes cannot be specified as source
volumes or target volumes.
The migration source volume and the migration
target volume is specified as LUSE volumes.
238B
Cancel the reservation by Business Copy, and then
migrate the volume.
The migration target volume is a reserved volume
of Business Copy.
238C
Perform the user authentication.
The command cannot be executed because the
user authentication is not performed.
9100
Make sure that the specified volume is
implemented.
The pair operation command was rejected
because the specified volume is not implemented.
B911
Make sure that the specified secondary volume is
implemented.
The pair operation command was rejected
because the specified secondary volume is not
implemented.
B912
Specify the mirror ID from 0 to 2.
The pair operation command was rejected
because the mirror ID is invalid.
B913