Domain management 48

The VC-FC SNMP settings apply to all VC-FC modules in the VC domain.

The following table describes the fields within the SNMP Configuration screen.

Field name

Description

Enable SNMP

Select to enable SNMP

System Contact

Specify a contact name for this system when SNMP is enabled

Read Community

Controls SNMP read access when SNMP is enabled. The default value for read
community string is "public". The read community string must always be set

when SNMP is enabled. The maximum length is 39 characters.

SNMP Trap Destinations

SNMP trap destination table.

Destination

User-designated name for the trap destination. The Destination name must be
unique.

IP Address

IPv4 address or DNS name for the trap destination

Community String

The Community String acts like a password for a given trap destination. The

trap receiving application can use the community string to filter the incoming
traps.
Default: public

Format

Format of the new trap. Select SNMPv1 or SNMPv2.

To add a trap destination, right-click on the header row of the destination table, and then select Add
Destination. See "Adding an SNMP trap destination (on page

46

)."