Network – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual
Page 40

Command line 40
Item Description
Enabled
(optional)
Enables or disables MAC cache failover. Valid values include "true" and "false".
Refresh
(optional)
The refresh interval for the MAC Cache (in seconds). Valid values include integers
from 1-30. The default refresh interval is 5 seconds.
Examples
->set mac-cache Enabled=true
Enables MAC Cache Failover
->set mac-cache Enabled=true Refresh=10
Enables MAC Cache Failover and sets the refresh interval
Item Description
show mac-cache
Display Ethernet MAC Cache failover settings.
Syntax
show mac-cache
Example
->show mac-cache
Displays Ethernet MAC Cache failover settings
network
Manage Virtual Connect Ethernet networks.
Supported actions: add, help, remove, set, show
Item Description
add network
Create a new Ethernet Network. After the network has been created, uplink ports
can be added if the network is not using a shared uplink port set.
The SmartLink property is no longer supported during the creation of the network. If
specified, it will be ignored. To configure the SmartLink attribute, use the set
network command.
Syntax
add network
VLanID=
[NativeVLAN=
[ConnectionMode=
[VLanTunnel=
[PrefSpeed=
[MaxSpeed=
Parameter
NetworkName
(required)
The unique name of the new network to create (required)
Option
Quiet
Suppresses user confirmation prompts during network creation and modification.
This option is used mainly in automated scripting scenarios.
Properties
UplinkSet
(optional)
The name of an existing shared uplink port set to use with this new network. If this
property is specified, then a valid VLAN ID must also be provided. The limit is 32
networks per shared uplink set.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem