Item Description
SharedServerVLanId
(optional)
Enables or disables the option to force server ports connected to multiple VC
Ethernet networks to use the same VLAN mappings as those used by
corresponding shared uplink sets. Valid values include: "true" and "false".
Setting the value to "true" restricts the server network connections to be selected
from a single shared uplink, and the VLAN ID cannot be modified.
Setting the value to "false" allows the user to select any VC Ethernet network for
the server Ethernet connections, and VLAN ID mappings can be modified to
ensure uniqueness.
SharedServerVLanId can be "true" only if VLanTagControl is set to "Map".
PrefSpeedType
(Optional)
Default connection speed for any Ethernet connection using multiple networks.
Valid values include "Auto" and "Custom". "Custom" allows the user to
configure the preferred speed. The default value is "Auto".
PrefSpeed (Required
if PrefSpeedType is
'Custom')
The default connection speed for any Ethernet connection using multiple
networks. Valid values range from: 100Mb-10Gb in 100Mb increments.
MaxSpeedType
(Optional)
Maximum connection speed for any Ethernet connection using multiple
networks. Valid values include "UnRestricted" and "Custom". "Custom" allows
the user to configure the preferred speed. The default value is "Unrestricted".
MaxSpeed (required
if MaxpeedType is
"Custom")
The maximum connection speed for any Ethernet connection using multiple
networks. Valid values range from: 100Mb-10Gb in 100Mb increments.
Examples
->set enet-vlan VLanTagControl=Map SharedServerVLanId=true
Sets the VLanTagControl to Map and SharedServerVLanId
->set enet-vlan PrefSpeedType=Custom PrefSpeed=500
MaxSpeedType=Custom MaxSpeed=2500
Sets the preferred connection speed for all connections using multiple networks
to 500Mb and maximum connection speed to 2.5Gb
Item Description
show enet-vlan
Display general Ethernet VLAN configuration settings.
Syntax
show enet-vlan
Example
->show enet-vlan
Displays Ethernet VLAN configuration settings
external-manager
Manage external manager settings and information.
Supported actions: remove, help, set, show
Item Description
show external-
manager
Display the information of an existing external manager.
Syntax
show external-manager
Example
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem