background image

Command line 33

interconnect

Manage I/O interconnect modules.
Supported actions: help, remove, show

Item Description

remove interconnect

Remove a module from the domain that has been removed physically from an

enclosure. Normally this command is used if a module has been physically
removed from the enclosure. To be removed, the module must not be currently

in use by any element in the domain.

Syntax

remove interconnect

Parameter

ModuleID(required)

The ID of the module to remove. The ID is in the format
:. To display a list of the IDs corresponding

to modules in the domain, the show interconnect command can be used.

Examples

->remove interconnect enc0:2
Removes a specific interconnect module (bay 2) from the domain

->remove interconnect *
Removes all interconnect modules from the domain that are not present
physically in any enclosures

->remove interconnect enc0:*
Removes all interconnect modules that are not present physically in a specific

enclosure

Item Description

show interconnect

Display all interconnect modules known to the domain.

Syntax

show interconnect [ModuleID|*]

Property

ModuleID

ID of the interconnect module. “*” displays detailed view of all the modules in
the VC domain. If not specified, summary output of all the modules is displayed

Examples

->show interconnect
Displays a summary listing of all interconnect modules

->show interconnect *
Displays detailed information for all interconnect modules

->show interconnect *:5
Displays the detailed information for all enclosures with interconnect modules
in interconnect bay number 5

->show interconnect enc0:*
Displays interconnect modules in all bays of a specific enclosure

->show interconnect enc0:3
Displays detailed information on a specific interconnect module in interconnect

bay 3 of the primary enclosure