Uplinkport – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual
Page 64

Command line 64
Item Description
->show systemlog -first=12
Displays the first twelve records from the system log
->show systemlog -last=8
Displays the last eight records from the system log
->show systemlog -last=20 -pause=6
Displays the last twenty records from the system log, six records at a time
To add a remote target, see "add log-target (on page
)."
uplinkport
Manage interconnect module uplink ports.
Supported actions: add, help, remove, set, show
Item Description
add uplinkport
Add a new uplink port to an existing network or a shared uplink port set.
Syntax
add uplinkport
UplinkSet=
[Role=
Parameter
PortID (required) The ID of an uplink port to add (required). The ID is a combination of the enclosure
name, interconnect bay, and port number in a single descriptor. The format of the
port name is "
Properties
Network
(optional)
The name of an existing network to which the port is added
UplinkSet
(optional)
The name of an existing shared uplink port set to which the port is added
Speed (optional) Specifies the port speed for the port (optional). Valid values include "Auto",
"10Mb", "100Mb", "1Gb", and "Disabled". If not specified, the default port speed
is "Auto".
Role (optional)
The role played by the port if the connection mode of the network or shared uplink
set is selected as "Failover". The default is "Primary".
Examples
->add uplinkport enc0:1:1 Network=MyNetwork
Adds a new uplink port (Bay 1, Port 1) to a network
->add uplinkport enc0:2:4 Network=MyNetwork Speed=1Gb
Adds a new uplink port (Bay 2, Port 4) to a network and sets the port speed
->add uplinkport enc0:2:3 UplinkSet=MyUplinkSet
Adds a new uplink port (Bay 2, Port 3) to a shared uplink port set
->add uplinkport enc0:2:4 Network=MyNetwork Role=Primary
Adds a new uplink port to a network with the connection mode as Failover and the
port role as Primary
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem