HP XP Continuous Access Software User Manual
Page 43
Continuous Access XP user guide for the XP1024/XP128
43
NOTE:
The scripting function is not supported for this version.
Continuous Access XP main pane (Pair Operation pane)
The first pane that appears after clicking the CA tab is the Continuous Access XP main pane, also known
as the Pair Operation pane. To display this pane, click Pair Operation on other Continuous Access XP
panes.
The Continuous Access XP main pane displays information about the selected CU image of the connected
disk array. From this pane, you can configure volume pairs. This section describes components of the
Continuous Access XP main pane. For information about Continuous Access XP volume pair configuration,
see ”
Performing Continuous Access XP pair operations
Information displayed on the Continuous Access XP main pane is updated when the Continuous Access
XP main pane is opened, the tab is switched from one to another, and Refresh (
) is clicked. The pair
information is also updated by clicking Apply.
RCU Operation
RCU Status
Displays RCU status and
Continuous Access XP
port numbers
that are already set.
RCU Operation >
Add RCU
Registers the RCU at the remote disk array. RCU controls the
S-VOL of the
Continuous Access XP
volume pair.
RCU Operation >
Delete RCU
Deletes RCUs that are already registered.
RCU Operation >
Change RCU Option
Modifies options for RCUs that are already registered.
Edit SSIS(s) & Path(s) >
Add Path
Adds paths to RCUs.
Edit SSIS(s) & Path(s) >
Delete Path
Deletes paths to RCUs.
Edit SSIS(s) & Path(s) >
Add SSID
Adds SSIDs of RCUs that are connected to the MCU.
Edit SSIS(s) & Path(s) >
Delete SSID
Deletes SSIDs of RCUs that are already connected to the MCU.
Port
Changes port types for the connected disk array.
Asynchronous
Operation
CT Group Operation >
CT Group Status
Displays information about consistency groups that are already
registered.
CT Group Operation >
Add CT Group
Assigns CUs to consistency groups.
CT Group Operation >
CT Group Option
Modifies settings for consistency groups that are already
assigned.
CT Group Operation >
Delete CT Group
Deletes consistency groups that are already assigned.
Async Option
Sets and modifies asynchronous copy options.
Usage Monitor
—
Collects and displays I/O statistics using the Remote Copy
Monitoring function.
History
Operations
—
Displays operation history of
Continuous Access XP
volume
pairs.
Table 12
Continuous Access XP functions (continued)
Tab
Menu command
Description