Chapter Five - SCSI Bridge Electronics
Tandem 5142-xSE Rackmount Tape Subsystems User Guide
2 8
5.13
Setup 3 Off-line Utilities Display Format Items
Hdwr
Test
PRESS to
Run
Enter
Set-Up 3
PRESS to
Select
Drive
Test
PRESS to
Run
Exit
Set-Up 3
PRESS to
Select
Load a
CodeTape
PRESS to
Run
Create a
CodeTape
PRESS to
Run
Figure 39
Setup 3 configuration items
Pressing the mode switch at this menu item invokes the drive self-test and offers a series of options from
which you may select. This is a standalone exerciser that may be used to diagnose problems within the
tape drive. Modes of operation include fixed/variable block transfers, spacing, differing
densities/compression modes and a means to control the running time. Records are written with
interspersed filemarks, rewound and read/verified. This cycle repeats for other densities supported by the
drive. During the whole testing process, you observe the error rate. If after using a new tape and cleaning
the heads, a high error rate persists, this would be suggestive of a drive problem. Other errors might
display the
KEY/ASC/ASCQ
bytes of a
Request Sense
command that are described in your
tape drive's user manual.
5.13.1
Invoking the drive test options
1M
Fixd.Tst
PRESS to
Run
1M
Vari.Tst
PRESS to
Run
Enter
Set-Up 3
PRESS to
Select
Drive
Test
PRESS to
Run
10M
Fixd.Tst
PRESS to
Run
10M
Vari.Tst
PRESS to
Run
200M
Fixd.Tst
PRESS to
Run
200M
Vari.Tst
PRESS to
Run
2.5G
Fixd.Tst
PRESS to
Run
2.5G
Vari.Tst
PRESS to
Run
Custom
Tst
PRESS to
Select
Exit
Menu
PRESS to
Select
Figure 40
Drive self-test options